CONTACT RELAY MODULE 24AC/2X21

Stock Code:
CRM24V-2X21
Regular Price: $50.20 (inc GST)
Regular Price:
$50.20 (inc GST)
Price:
$46.01 (inc GST)
Quantity Breaks
1+
$46.01 (inc GST)

Description

Relay Module - RIF-1-RPT-LV-24AC/2X21

Pre-assembled relay module with Push-in connection, consisting of: relay base, power contact relay, plug-in display/interference suppression module, and retaining bracket. Contact type: 2 changeover contacts. Input voltage: 24 V AC

Dimensions

Width

16 mm

Height

96 mm

Depth

75 mm

Hole Diameter

3.2 mm

 

Ambient conditions

Ambient temperature (operation)

-40 °C ... 55 °C

Ambient temperature (storage/transport)

-40 °C ... 85 °C

 

Coil side

Nominal input voltage UN

24 V AC

Input voltage range

19.2 V AC … 27.6 V AC (20 °C)

Input voltage range in reference to UN

See diagram

Typical input current at UN

33 mA

Typical response time

3 ms … 12 ms

Typical release time

3 ms … 20 ms

Protective circuit

Varistor

Operating voltage display

Yellow LED

Power dissipation for nominal condition

0.79 W

Contact side

Contact type

2 changeover contact

Type of switch contact

Single contact

Contact material

AgNi

Maximum switching voltage

250 V AC/DC

Minimum switching voltage

5 V (at 10 mA)

Min. switching current

10 mA (5 V)

Maximum inrush current

12A (20 ms, N/O contacts)

Limiting continuous current

8 A

Interrupting rating (ohmic load) max.

 

 

 

 

 

192 W (at 24 V DC)

96 W (at 48 V DC)

60 W (at 60 V DC)

44 W (at 110 V DC)

57 W (at 220 V DC)

2000 VA (for 250 V AC)

Switching capacity

 

2 A (at 24 V, DC13)

 

0.2 A (at 250 V, AC15)

 

3 A (at 24 V, DC13)

 

3 A (at 120 V, AC15)

 

3 A (at 250 V, AC15)

Connection data input side

Connection method

Push-in connection

Stripping length

8 mm

Conductor cross section solid

0.14 mm² ... 1.5 mm²

Conductor cross-section flexible

 

 

0.14 mm2 … 1.5 mm2

0.2 mm² ... 1.5 mm² (Ferrule with plastic sleeve)

0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)

Conductor cross section AWG

 

26 … 16 (solid)

26 … 16 (flexible)

General

Test voltage winding/contact

4 kVrms (50 Hz, 1 min.)

Test voltage changover contact/changeover contact

2.5 kVrms (50 Hz, 1 min.)

Operating mode

100% operating factor

Degree of protection

IP20 (Relay base)

RT III (Relay)

Mechanical service life

approx. 107 cycles

Mounting position

Any

Assembly instructions

In rows with zero spacing

 

Standards and Regulations

Standards/regulations

DIN EN 50178

Insulation

Basic insulation between the changeover contacts

Safe isolation between input and output

Degree of pollution

2

Overvoltage category

III

Flammability rating according to UL 94

V2 (Housing)