- Home /
- ELECTRICAL COMPONENTS /
- PHOENIX CONTACT /
- RELAY MODULE SCREW CONNECTION 24AC 4X21
Shop Now
-
HVACR SPARES & EQUIPMENT
- ACTRONAIR & CONTROLS
- SAMSUNG
- ACTRON CONTROLS
- EVCO CONTROLS
- EMERSON/COPELAND
- COMMERCIAL KITCHEN VENTILATION
- EVAPORATORS
- CONDENSING UNITS
- CONDENSERS
- BITZER
- EMBRACO
- AIREF
- FRASCOLD
- DANFOSS
- SANHUA
- RANCO CONTROLS
- REGAL
- AXIAL FANS, MOTORS & BLADES
- SYSTEM COMPONENTS
- COMMERCIAL COMPRESSORS
- CONTROLS
- DEFROST CONTROLS
- SKOPE
- KULTHORN KIRBY
- REFRIGERATION HARDWARE
-
HVACR SERVICE TOOLS
- SUPERCOOL HVACR
- RECLAIM UNITS
- VACUUM PUMPS
- LEAK DETECTORS
- REFRIGERANT SCALES
- MANIFOLDS, GAUGES & HOSES
- REGULATORS
- OXY SETS/BRAZING TORCHES/ETC
- DISPOSABLE BOTTLES
- BRAZING
- UV DETECTION/INJECTION KITS
- CHEMICALS
- SUPER SEAL/CLIPLIGHT
- REPAIR PATCHES
- TOUGH TOOL BAGS, VETO PRO PAC
- THERMOMETERS
- HAND TOOLS
- TEST & MEASUREMENT
- GENERAL HVACR TOOLS
- TAPES/GLUES/PAINTS/ACCS'/ETC
- FIRE EXTINGUISHERS
- ADAPTORS & ACCESSORIES
- MISCELLANEOUS
- BLACK DIAMOND TOOLS
- REFRIGERANT & EMPTY CYLINDERS
- COPPER PIPE & FITTINGS
-
AIR CONDITIONING
- AC SYSTEMS
- A SAUERMANN PUMPS
- COPPER FITTINGS
- ASPEN PUMPS
- HANWEST CONTROLS
- BIG FOOT SUPPORT SYSTEMS
- CONDENSATE PUMPS
- AIR CONDITIONING FILTERS
- WALL & ROOF BRACKETS
- PVC/PLASTIC DUCT & FITTINGS
- DRAIN PIPE & ACCESSORIES
- MOUNTING FEET & SLABS
- AIR DIFFUSERS & FLEXIBLE DUCTS
- A/C INSTALLATION ACCESSORIES
- COLOURBOND TRUNKING
- UNIVERSAL REMOTES
- THERMOSTATS
- GLYCOL
- TESTO EQUIPMENT
- MECHANICAL SERVICE EQUIPMENT
- ELECTRICAL COMPONENTS
- AUTOMOTIVE
- DOMESTIC REFRIGERATION
-
HEATING SPARES & EQUIPMENT
- BAIN MARIE EQUIPMENT
- HOT WATER SPARE PARTS
-
STOVE/OVEN/GRILL SPARE PARTS
- FAN MOTORS & ACCESSORIES
- THIN COIL ELEMENTS
- MONOTUBE ELEMENTS
- SOLID HOTPLATES
- UNDERGLASS HILIGHT ELEMENTS
- OVEN FAN FORCED ELEMENTS
- OVEN &/OR GRILL ELEMENTS
- BOWLS & PANS
- RINGS & SOCKETS
- DOOR HINGES
- THERMOSTATS
- CONTROLS
- SWITCHES & INDICATORS
- TERMINALS & CONNECTORS
- OVEN KNOBS, CABLES & SEALS ETC
- GAS COOKTOP SPECIFIC PARTS
- MISCELLANEOUS
- EGO
- WATER FITTINGS & ACCESSORIES
- CAPACITORS
-
GENERAL APPLIANCE SPARES
- DISHWASHER PARTS
- DOOR INTERLOCKS
- DRYER PARTS
- FISHER & PAYKEL PARTS
- GE PARTS
- HOOVER PARTS
- HOOVER TWIN TUB
- HOSES, CLAMPS, CONNECTORS ETC.
- KLEENMAID PARTS
- LG PARTS
- MAYTAG PARTS
- MOTOR BRUSHES
- SIMPSON PARTS
- UNIVERSAL BEARINGS
- UNIVERSAL PARTS & ACCESSORIES
- V, DRUM & BLOWER BELTS
- WHIRLPOOL PARTS
- MISCELLANEOUS
RELAY MODULE SCREW CONNECTION 24AC 4X21
Description
Relay Module - RIF-2-RSC-LV-24AC/4X21
Pre-assembled relay module with screw connection, consisting of: relay base, power contact relay, plug-in display/interference suppression module, and retaining bracket. Contact type: 4 changeover contacts. Input voltage: 24 V AC
Dimensions
Width | 27 mm |
Height | 89 mm |
Depth | 75 mm |
Ambient conditions
Ambient temperature (operation) | -40 °C ... 50 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Coil side
Nominal input voltage UN | 24 V AC |
Input voltage range in reference to UN | see diagram |
Typical input current at UN | 66 mA |
Typical response time | 5 ms … 15 ms |
Typical release time | 5 ms … 20 ms |
Coil voltage | 24 V AC |
Protective circuit | Varistor |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 1.58 W |
Contact side
Contact type | 4 changeover contacts |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC |
Minimum switching voltage | 5 V (at 24 mA) |
Min. switching current | 5 mA (at 24 V) |
Maximum inrush current | 16 A (20 ms, N/O contacts) |
Limiting continuous current | 5 A (see diagram) |
Interrupting rating (ohmic load) max.
| 120 W (at 24 V DC) |
124 W (at 48 V DC) | |
108 W (at 60 V DC) | |
52 W (at 110 V DC) | |
48 W (at 220 V DC) | |
1250 VA (for 250 V AC) | |
Switching capacity
| 2 A (at 24 V, DC13) |
0.22 A (at 120 V, AC15) | |
0.11 A (at 250 V, DC13) | |
1.5 A (at 24 V, AC15) | |
1.5 A (at 120 V, AC15) | |
1 A (at 240 V, AC15) |
Connection data input side
Connection method | Screw connection |
Stripping length | 8 mm |
Conductor cross section solid | 0.5 mm² ... 4 mm² |
Conductor cross-section solid (2 conductors with same cross section) | 0.5 mm2 … 2.5 mm2 |
Conductor cross section flexible
| 0.5 mm² ... 4 mm² |
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve) | |
Conductor cross section flexible (2 conductors with same cross section) | 0.5 mm2 … 2.5 mm2 |
0.5 mm2 … 1.5 mm2 (TWIN ferrule with plastic sleeve) | |
Conductor cross section AWG
| 20 ... 10 (solid) |
20 … 12 (flexible) |
General
Test voltage winding/contact | 2.5 kVrms (50 Hz, 1 min.) |
Test voltage contact/contact | 2 kVrms (50 Hz, 1min., contact/contact) |
Operating mode | 100% operating factor |
Degree of protection
| IP20 (Relay base) |
Mechanical service life | approx. 2 x 107 cycles |
Mounting position | Any |
Assembly instructions | In rows with zero spacing |
Standards and Regulations
Standards/regulations | DIN EN 50178 |
Insulation | Basic insulation |
Degree of pollution | 2 |
Overvoltage category | II |
Flammability rating according to UL 94 | V2 (Housing) |