SCHNEIDER MULTI FUNCTION TIMER 1s 10h

Stock Code:
SE-MFTR01
Regular Price: $126.47 (inc GST)
Regular Price:
$126.47 (inc GST)
Price:
$115.93 (inc GST)
Quantity Breaks
1+
$115.93 (inc GST)

Details

  • In Stock Unit:
    EACH

Description

MAIN

range of productHarmony Timer Relays
product or component typeMultifunction relay
discrete output typeRelay
width17.5 mm
device short nameRE17R
time delay typePower on-delay
Interval
Off-delay
Symmetrical flashing
time delay range6...60 min
1...10 min
1...10 s
1...10 h
6...60 s
0.1...1 s
nominal output current8 A

COMPLEMENTARY

contacts type and composition1 C/O
contacts materialCadmium free
height90 mm
depth72 mm
control typeSelector switch front panel
[Us] rated supply voltage24...240 V AC 50/60 Hz
24 V DC
voltage range0.85...1.1 Us
supply frequency50...60 Hz +/- 5 %
release of input voltage10 V
connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
tightening torque0.6…1 N.m conforming to IEC 60947-1
housing materialSelf-extinguishing
repeat accuracy+/- 0.5 % conforming to IEC 61812-1
temperature drift+/- 0.05 %/°C
voltage drift+/- 0.2 %/V
setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
control signal pulse width100 ms with load in parallel typical
30 ms typical
insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
reset time120 ms on de-energisation typical
on-load factor100 %
power consumption in VA0…32 VA at 240 V AC
maximum power consumption in W0.6 W at 24 V DC
minimum switching current10 mA at 5 V DC
maximum switching current8 A AC/DC
maximum switching voltage250 V AC
breaking capacity2000 VA
operating frequency10 Hz
electrical durability100000 cycles (8 A at 250 V AC maximum) for resistive load
mechanical durability10000000 cycles
dielectric strength2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage5 kV during 1.2/50 µs
power on delay100 ms
markingCE
creepage distance4 kV/3 conforming to IEC 60664-1
safety reliability dataMTTFd = 296.8 years
B10d = 270000
mounting positionAny position in relation to normal vertical mounting plane
mounting support35 mm DIN rail conforming to EN/IEC 60715
local signallingLED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
net weight0.07 kg
time delay typeA, At, B, C, D, Di, H, Ht
functionalityMultifunction
compatibility codeRE17

ENVIRONMENT

immunity to microbreaks20 ms
standards2004/108/EC
EN 61000-6-2
EN 61000-6-3
EN 61000-6-1
2006/95/EC
IEC 61812-1
EN 61000-6-4
product certificationsCSA
cULus
ambient air temperature for storage-30…60 °C
ambient air temperature for operation-20…60 °C
IP degree of protectionIP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
vibration resistance20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
relative humidity93 % without condensation conforming to IEC 60068-2-30
electromagnetic compatibilityElectrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022

PACKING UNITS

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight81.0 g
Package 1 Height2.8 cm
Package 1 width7.8 cm
Package 1 Length9.6 cm
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Weight3.74 kg
Package 2 Height15 cm
Package 2 width30 cm
Package 2 Length40 cm